HomeMy WebLinkAboutORD 2050 Amending Appendix C of the Code - ConstructionCity of West University Place
Harris County, Texas
ORDINANCE NO. 2050
AN ORDINANCE OF THE CITY OF WEST UNIVERSITY PLACE, TEXAS
AMENDING APPENDIX C, TECHNICAL CODES SCHEDULE, OF THE WEST
UNIVERSITY PLACE CODE OF ORDINANCES BY ADOPTING THE 2018
EDITION OF THE INTERNATIONAL BUILDING CODE; ADOPTING THE 2018
EDITION OF THE INTERNATIONAL RESIDENTIAL CODE; ADOPTING THE
2018 EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE;
ADOPTING THE 2018 EDITION OF THE INTERNATIONAL FIRE CODE;
ADOPTING THE 2018 EDITION OF THE INTERNATIONAL PLUMBING CODE;
ADOPTING THE 2018 EDITION OF THE INTERNATIONAL MECHANICAL
CODE; ADOPTING THE 2018 EDITION OF THE INTERNATIONAL
PROPERTY MAINTENANCE CODE; ADOPTING THE 2018 EDITION OF THE
INTERNATIONAL FUEL GAS CODE; ADOPTING THE 2018 EDITION OF THE
INTERNATIONAL SWIMMING POOL AND SPA CODE; ADOPTING THE 2017
EDITION OF THE NATIONAL ELECTRICAL CODE; AND PROVIDING FOR
THE ADOPTION OF LOCAL AMENDMENTS THERETO.
WHEREAS, the building official of the City of West University Place, Texas, has
proposed to amend the Technical Codes Schedule by adopting updated editions of the
standard codes that are incorporated into the Code of Ordinances, local amendments to
the standard codes and related amendments to Code of Ordinance provisions; and
WHEREAS, such updates and amendments were referred to the Building & Standards
Commission, which has recommended them for consideration and adoption by the City
Council; and
WHEREAS, the City Council of the City of West University Place, Texas now finds that
it is necessary and proper to update and amend the Technical Codes Schedule, the
local amendments thereto, and related Code of Ordinance provisions.
NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY
OF WEST UNIVERSITY PLACE, TEXAS THAT:
Section 1. The Code of Ordinances of the City of West University Place, Texas
is amended as indicated in the chart below and to read as set out in the Exhibit A,
attached hereto and made a part of this ordinance, as follows:
Code Cha ter
Section
Amendment
Appendix C.
Adopt the updated editions of the standard
Technical
codes that are incorporated into the Code of
Codes
Ordinances
Schedule
Section C -109
Revise no. 4 to adopt a provision regarding
PVC joint surfaces
Section C -109
Revise no. 4 to adopt a provision regarding
the installation of water heaters in certain
locations
(00196512.docz)
City of West University Place
Harris County, Texas
Section 2. All other portions of the Code of Ordinances not specifically
amended hereby remain in full force and effect.
Section 3. All ordinances and parts of ordinances in conflict with this
Ordinance are repealed to the extent of the conflict only.
Section 4. If any word, phrase, clause, sentence, paragraph, section or other
part of this Ordinance or the application thereof to any person or circumstance, shall
ever be held to be invalid or unconstitutional by any court of competent jurisdiction,
neither the remainder of this Ordinance, nor the application of such word, phrase,
clause, sentence, paragraph, section or other part of this Ordinance to any other
persons or circumstances, shall be affected thereby.
Section 5. The City Council officially finds, determines and declares that a
sufficient written notice of the date, hour, place and subject of each meeting at which
this Ordinance was discussed, considered or acted upon was given in the manner
required by the Texas Open Meetings Act, as amended, and that each such meeting
has been open to the public as required by law at all times during such discussion,
consideration and action. The City Council ratifies, approves and confirms such notices
and the contents and posting thereof.
Section 6. This Ordinance takes effect immediately upon its passage and
adoption on second reading.
PASSED, APPROVED AND ADOPTED ON FIRST READING on the 14th day
of May 2018.
ZSSED, APPROVED AND ADOPTED ON SECOND READING, AND
th 151 day of May 2018.
W -� ' T*' Signecl TBxAS City Secretary eal) Mayor
Recommended:
City Manager
Approved as to legal form:
City Attorney
(00196512.dacz (
City of West University Place
Harris County, Texas
Exhibit A
(Amended Appendix C- Technical Codes Schedule, Code of Ordinances)
APPENDIX C
TECHNICAL CODES SCHEDULE
International Building Code (IBC), 2018 Ed., International Code Council, Inc.
International Energy Conservation Code (IECC), 2018 Ed., International Code
Council, Inc.
International Fire Code (IFC), 2018 Ed., International Code Council, Inc.
International Fuel Gas Code (IFGC), 2018 Ed., International Code Council, Inc.
International Mechanical Code (IMC), 2018 Ed., International Code Council, Inc.
International Plumbing Code (IPC), 2018 Ed., International Code Council, Inc.
International Residential Code (IRC), 2018 Ed., International Code Council, Inc.
National Electrical Code (NEC), 2017 Ed., National Fire Protection Association,
( "NEC')
International Property Maintenance Code (IPMC), 2018 Ed., International Code
Council, Inc.
International Swimming Pool and Spa Code (ISPSC), 2018 Ed., International
Code Council, Inc.
(00196512.docx (
City of West University Place
Harris County, Texas
Sec. C -109. - International Plumbing Code.
The administrative officer is the building official. Chapter 18 of this Code shall apply to enforcement
and administration of this code in the same manner as it applies to the building code. The BSC shall
have the same jurisdiction and authority with respect to the code as it has with respect to the building
code.
2. Delete: All appendices to and sections P103, P106 and P109 of the International Plumbing Code.
3. Even if otherwise permitted by the IPC;
a. Acrylonitrile- Butadiene - Styrene (ABS) pipe and fittings, Type M copper, lead- based pipe,
aluminum DWV pipe and components are not approved materials for use. Air admittance valves
are only approved for use in an unenclosed structure, I. e. outdoor kitchen.
b. Polybutylene, Polyethylene (PB, PE, PEX -AL -PEX, PE- AL -PE) are forbidden to be used for
water service or distribution piping in concealed spaces (including attics).
c. The jointing procedure approved for PEX -a shall be a procedure utilizing ASTM F 1960 Fittings
and PEX Rings, only.
d. Should a PEX -a or CPVC manifold system be Installed it shall not be located on a wall shared
with a garage.
4. Even if otherwise permitted by the IPC:
a. PVC type water pipe and fittings are not allowed for use in the City. Exceptions: (A) Schedule 40
meeting ASTM D1785 (or better) PVC water pipe may be used where permitted by the IPC, but
only if: (i) it is installed underground (but see next paragraph requiring copper lines in some
locations) or as pool piping, (ii) all joints are primed and glued as required by the manufacturer's
recommendations (and the primer must be purple or another distinctive color, except on above-
ground pool piping), and (iii) it is identified by proper markings. (B) This section does not apply
to irrigation systems.
b. PVC joint surfaces shall be clean and free from moisture. A primer that conforms to ASTM F656
shall be applied before solvent cementing.
bc. All water lines under a slab on grade must be copper Type L, K or PEX -a. Each water line
under, in or through a slab on grade must be sleeved with a continuous piece of tubing at least
0.025 inches thick terminating at least six inches above the finished floor.
ed. Irrigation systems must meet these criteria: (i) Schedule 40 PVC material meeting ASTM D1785
(or better) must be used for pressure lines. (ii) Class 160 PVC material (or better) must be used
for field lines. (iii) All lines shall be buried at least six inches below grade. Note: The City is not
responsible for irrigation system components located in street areas or easements (and special
permits may be required to install such components in those locations; see, e.g., Chapter 70 of
this Code).
de. Underground water service piping must be buried at least 12 inches below grade.
f. Water heaters installed in a location where water leakage from the tank will cause damage shall
be placed in an approved pan with a drain to the exterior in accordance with the IPC.
eg. PVC drain, waste or vent pipe and fittings must be Schedule 40 meeting ASTM D2665 (or
better) and identified by proper markings. Exception; Area drain piping may be SDR 35 PVC.
5. Amend Section 916.3 to read as follows: 'The vent located below the flood level rim of the fixture
being vented shall be installed below the floor using drainage pattern fittings with a fall of not less
than one - quarter inch (1/4 ") per foot to the drain. The vent shall be sized in accordance with Section
906.2 with 2 "diameter pipe being the minimum. The lowest point of the island fixture vent shall
connect full size to the drainage system. The vent or branch vent shall extend as high as practicable,
but not below the drain board. There shall be a vent loop at the top of the fixture riser. The fittings
shall prevent a horizontal segment at the top of the loop. Cleanouts shall be provided in the island
(00196512.doa )
City of West University Place
Harris County, Texas
fixture drain and vent to permit rodding of all piping located below the flood level rim of the fixtures.
Rodding in both directions shall be permitted through a cleanout."
B. Amend Section 1101.2 to read in its entirety as follows: 'The provisions of this chapter are applicable
to interior leaders, building storm drains, building storm sewers, exterior conductors, downspouts,
roof gutters and other storm drainage fixtures and facilities."
7. Maximum water meter size, unless an RPE (Registered Professional Engineer) can clearly
and convincingly demonstrate the need for a larger meter in a particular case, is:' /, -inch for an
irrigation system, or 1 -inch for a single - family dwelling.
(Addition shown by underline; deletion shown by strike -out)