Loading...
HomeMy WebLinkAbout02022006 BSC Agenda Item 5 • • STAFF REPORT BUSINESS OF THE BUILDING STANDARDS COMMISSION CITY OF WEST UNIVERSITY PLACE, TEXAS AGENDA OF: February 2, 2006 Agenda Item: #5 DATE SUBMITTED: January 27, 2006 DEPARTMENT OF ORIGIN: Development Services PREPARED BY: D. Scarcella PRESENTER: D. Scarcella SUBJECT: Proposed amendment to the Technical Codes Schedule, Structural Framing Regulations. EXHIBITS: Proposed structural framing ordinance provisions EXECUTIVE SUMMARY Attached is the final proposed structural framing provision with corrections requested at the BSC workshop on January 30, 2006. If approved, this proposed ordinance will be presented to City Council during the last meeting in February 2006. • Draft amendment of the Technical Codes Schedule regarding structural framing and related elements revised 1-30-06 Technical Codes Schedule Adoption. Subject to the amendments and deletions indicated beneath each code, each of the following codes, including all of its published appendices and attachments, is adopted, ordained and made a part of the Code of Ordinances of the City and of each chapter where it is referenced, except as otherwise expressly provided. Procedure for amendments,etc. The procedure for adopting new codes, updated codes, local amendments and provisions for administration and enforcement of these codes is as follows: (1)proposal by the building official or other appropriate City official, (2)referral to the Building&Standards Commission, (3)consideration by the City Council, after giving required meeting notices, and(4)adoption and publication, as required by Article II of the City Charter. International Building Code, 2003 Ed.,International Code Council, Inc. 5. A.) All walls and ceilings within a R-1, R-2, R-3 and R-4 type occupancy shall be sheathed with Type X gypsum board at least 5/8-inch(15.9 mm) thick. Exception: Where this code (IBC, MC)requires otherwise for moisture protection. B.) Structural Elements; Engineering, Etc. (1) The structural elements for the following must meet the criteria in this section, as applicable: (a) each new building(and each addition to an existing building) containing habitable space and having either a gross floor area of 485 square feet or more or a floor higher than four feet; and (b) each accessible deck, porch,balcony, walkway and similar structure with a finished floor height greater than four feet. [Note: Unless otherwise defined, "height" is measured from the "standard base level"as provided in the Zoning Ordinance./ (2) This section does not apply to foundation elements observed and certified under another section. Page 1 • • (3) In this section: "A2LA Lab"means a laboratory accredited by the American Association for Laboratory Accreditation on the basis of ISO/IEC 17025:1999 ("general requirements for the competence of testing and calibration laboratories"). "RLPE"means a registered or licensed professional engineer of the State of Texas who is: (a) listed with the State Board of Professional Engineers in either the civil or structural branch of engineering(but, from and after May 1, 2006, listing in the structural branch is required); (b) employed by a registered engineering firm of the State of Texas; and (c) covered by professional errors and omissions insurance that: (i) has limits of at least $250,000 per claim(and at least $500,000 per year, aggregate) and(ii) has effective dates—including any retroactive coverage date—that include the entire period when the person provides services or takes actions regulated by this section. C. Engineering; Plans &Specifications. Structural elements must be constructed in accordance with complete plans and specifications prepared, signed and sealed by a RLPE. The plans and specifications must be prepared specifically for the structure in question, and they must meet criteria as to scope, content and form specified by the building official. D. Specific Requirements. (1) Framing; Sheathing. All framing must include full exterior sheathing with structural elements (or blockingl along all joints. The plans must indicate the type, size and spacing of fasteners. All sheathing must be minimum 7/16" structural wood panels. (2) Trusses, Joists, Etc. (a) The species and grade of all lumber used for trusses,joists,purlins, purlin supports or similar elements must be specified in the plans. (b) The length, spacing and direction of trusses and joists must be Page 2 . • specified in the plans. (c) Each manufactured wood truss must comply with applicable requirements of the "National Design Standard For Metal Plate Connected Wood Truss Construction"published by Truss Plate Institute (TPI), 1- 2000 Ed. E. Observation & Certification. Structural elements must be professionally observed and must be certified by an RLPE, as more fully described below: (1) Observations must: (a) be performed either by the certifying RLPE or by one or more persons under that RLPE's direct supervision and control whose professional qualifications are approved by the RLPE, (b) include actual observation of structural elements and attachments in crawl spaces before they are covered by floors or other materials, (c) include actual observations of each beam,joist, rafter, truss and similar element, including each related weld and high-strength bolt: (i) after all required plumbing, electrical and mechanical"rough-in"inspections have been passed and all expected"notching,"boring and similar work has been done, and(ii)before the item is covered, and (d) be documented in a form and manner approved by the building official (which may include photographs). (2) Certifications must: (a) refer to and be based upon the professional observations required by this section, (b) state that the portions of the work required to be observed comply with the plans and specifications last approved by the building official (with any field changes that are ordered by the RLPE, reported to the building official and in compliance with applicable regulations), (c) comply with criteria as to form and content as may be specified by the building official, (d) be signed and sealed by the certifying RLPE, and (e) be filed with the building official. Page 3 • (3) Certifications may rely in part upon attached certifications by: (i) an A2LA Lab, as to materials testing, and(ii) an inspector certified by the City of Houston, as to welds or high-strength bolts (or meet the provisions of Section 1704.3.3 of the IBC). Before any a beam, joist, rafter, truss, weld, high-strength bolt or similar element is covered: (i) all required city inspections relating to that element must be passed, and(ii) the permittee must obtain written acknowledgment from the building official that the certification for that element was duly filed as required above. For any given building, there may be more than one certification filed. After a beam,joist, rafter, truss, weld, high-strength bolt or similar element has been observed and certified, as provided above, it may not be notched, bored or structurally altered without: (i) a new or amended permit, if required, and(ii) a new observation and certification, in accordance with this section. Certifications,plans, specifications and related items may be kept on file by the City, for public inspection, for an indefinite period of time. F. Special Exceptions. The BSC may issue a special exception from any requirement in subsection"a"through"d", above, but only upon a showing that: (1) the requirement will not affect life safety or the performance of a structure (for its estimated useful life); or (2) an alternate requirement to be imposed by the special exception will provide equal or better protection for life safety and long-term structural performance. In connection with any such special exception, the BSC may require that the applicant provide supporting engineering data and opinion, and the BSC may impose conditions to carry out the purpose and intent of applicable regulations. Page 4 • • FRAMING CERTIFICATE Unless otherwise indicated,word and phrases used in this document have the same meanings as in The Technical Codes Schedule of the Code of Ordinances ("Foundation Ordinance')of the City of West University Place, Texas("City'). Subject: New structural frame built at the site described below("New Structural Frame") Address of site: Legal description of the site: Building Permit No: Permittee: CERTIFICATION: By signing below, I certify as follows (check applicable sections): ( ) I am an"RLPE"as defined in the Structural Framing Ordinance. ("RITE"means a registered or licensed professional engineer of the State of Texas who is:(1)listed with the State Board of Professional Engineers in either the civil or structural branch of engineering(but,from and after May 1,2006,listing in the structural branch is required);(2)employed by a registered engineering firm of the State of Texas;and(3)(unless waived by the BSC),covered by professional errors and omissions insurance that:(i)has limits of at least$250,000 per claim(and at least$500,000 per year,aggregate) and(ii)has effective dates—including any retroactive coverage date—that include the entire period when the person provides services or takes actions regulated by this section.] ( ) Observations of the New Structural Frame: ( ) were performed either by me or by one or more persons under my direct supervision and control whose professional qualifications were approved by me; ( ) included actual observations of structural elements and attachments in crawl spaces before they are covered by floors or other materials. ( ) include actual observations of each beam,joist,rafter, truss and similar element, including each related weld and high-strength bolt: a) after all required plumbing, electrical and mechanical "rough-in"inspections have been passed and all expected notching,boring, and similar work has been done, and b) before the item is covered. ( ) were documented in a form and manner approved by the building official of the City. ( ) Referring to and based upon the professional observations described above,the New Structural Frame complies with the plans and specifications last approved by the building official (with any field changes that were ordered by me and reported to the building official and that comply with applicable regulations). ( ) This certification does not rely upon any other certification, except as indicated below: optional, with attachment( ) This certification relies in part upon an attached certification by an A2LA Lab, as to materials testing. optional, with attachment( ) This certification relies in part upon an attached certification by an inspector certified by the City of Houston or in compliance with Section 1704.3.3 of the IBC, as to welds or high-strength bolts. Name of certifying RLPE (printed): Date signed: Employed by(name of registered engineering firm): Signature of RLPE: Texas Registration Number: (SEAL) must be legible ACKNOWLEDGMENT OF FILING.The building official of the City acknowledges that this certification was duly filed as required by the Structural Framing Ordinance. By: Date acknowledged: