Joint Preliminary Report
Zoning and Planning Commission (ZPC) & Building and Standards Commission (BSC)
September 22, 2008
Sub ct
Basements/Underground Structures
Background
Recently, City Planner, Debbie Scarcella, alerted the ZPC and BSC to the fact that builders in
WestUniversity Place are beginning to include subterranean structures (basements) in their projects.
(See Attachment "A"). In the past year or so, three separate permit applications have included either
partial or full basement structures. The city's zoning regulations (Code of Ordinances, Appendix A) and
building and development regulations (Code of Ordinances, Chapter 18) do not specifically address
regulating such structures. The International Building Code and International Residential Code include
specific technical regulations when constructing the structures, but do not address such issues as
location on the building site, proximity to property lines, maximum depths, uses of the space, etc. The
city's floodplain regulations address basements in a special flood hazard area, but not in the non-hazard
areas of the city.
After preliminary discussions and research into the existing regulations, the ZPC and BSC have
concluded that basements present potential risks to both property owners and occupants, and the city's
ordinances should be amended to address them. Philosophically, there are two approaches the city can
take. The first would be to institute a broad prohibition of subterranean structures by simply not
allowing them. The second would be to allow them within strict regulations.
Prohibition
To take the broad prohibition approach, the city would need to amend specific sections of the
Code of Ordinances, either through the zoning regulations or building and development regulations and
building codes. There are definite pros and cons to this approach.
Pros
1. Simplicity. Would add very little to the Code of Ordinances. Removes/resolves nearly all
questions (e. g., proximity to property lines, possible impacts on adjoining properties of
narrow sites, lateral and subjacent support of structures, flooding, emergency egress,
framed area, number of stories).
2. Helps control density and intensity of use and the possible increased burden on city
infrastructure.
3. Creates uniformity across the city as to the impacts on flood risks and fire safety.
Basements are already prohibited in the 100-year flood plain.
Cons
1. Possibly encroaches on the rights of property owners.
2. Prevents some traditional uses of subterranean spaces (e.g., storm or wine cellar,
mechanical equipment, storage, etc.)
Allow. But Regulate
Pros
1. Gives property owners more flexibility in how to use their property (protects property
owner's rights).
2. Might bolster the tax base by increasing the appraisal and creating a more desirable
property for someone who would prefer, for example, a basement mechanical area or wine
cellar.
3. Could act as a possible storm cellar when weather conditions deteriorate, or allow other
desirable traditional uses.
4. Regulations would contribute to making the spaces safe from flooding and fire.
Cons
1. Possible impact on neighbors, especially on narrow lots that utilize a full basement
approach.
2. Possible impact on density and infrastructure by placing an extra burden on utilities, parking
and traffic, etc.
3. Increases property-damage and personal-safety risks in a flood situation or fire.
The ZPC and BSC have discussed and developed additional issues to consider if the
allow-but-regulate approach is taken. These issues are listed Attachment "B" to this report.
Action
The commissioners and staff seek direction from City Council regarding appropriate action on this
subject, including the choice of approach. We look forward to discussing this topic in a workshop
session with City Council, if desired.
Best Regards,
Steve Brown, Chair ZPC Bryant Slimp, Chair BSC
Attachment "A"
EXCAVATIONS AND UNDERGROUND STRUCTURES
June 9, 2008
The key issues regarding excavations and underground structures are as follows:
1. A. Should the underground structure project into the yards and if so, then how much?
Should the excavation area be allowed to project into the yards? (ZPC)
Table 7-6 of the Zoning Regulations lists those items allowed to project into the regulated
yards. Underground items are not restricted at all as to the limits of their encroachment
into these yards. Conceivably, a basement would technically be allowed to span. the
entire building site from property line to property line unrestricted.
B. Should underground structures be allowed on narrow lots taking the 3/7 alternate side
yard exception?
Narrow lots (Less than 55' wide) are given an option to use alternate side yards. This is
allowed to encourage rear situated garages. If a structure built underground on a narrow
site is constructed when taking the alternate side setback allowance, should there be
limits and restrictions on the proximity of the basement wall. and the excavation to
adjoining property lines.
2. If an underground structure is allowed in the yard areas, should there be special rules for
lot drainage regulations? (BSC)
Chapter 1.8 provides regulations for building site drainage and controlling the runoff rate
based on a 1" per hour rainfall. Slabs on grade will provide a small amount of pervious
area underneath the foundation for water absorption. If a full basement is built, will this
impact the drainage in a significant enough manner to require additional drainage
measures not specified in Chapter 18?
3. Underground structures in the 100 year floodplain are strictly controlled. Should there be
additional regulatory language controlling the basements outside the 100 year
floodplain?(BSC)
Enclosed portions of structures located in the 1.00 year floodplain which. are below the
base flood elevation are not allowed unless they meet criteria established in Section R323
of the 2003 IRC and Chapter 18 Article IX of the city's Code of Ordinances. There are
no similar regulations for structures outside the floodplain.
Attachment "A"
4. Should there be additional engineering criteria for the foundations of underground
structures? (BSC)
Appendix C of the Code of Ordinances deals with the Technical Codes and amendments
to those codes. West U has amendments dealing with requirements for different types of
foundations. Basement walls are not addressed in this amendment. Section R403 of the
2003 IRC addresses some aspects of basement construction, but does not address
proximity to adjacent sites, depth of excavation, etc.
5. Should the area included within the walls of an underground structure be counted toward
framed area? (ZPC)
Framed area definition in Article 2 of the Zoning Regulations lists basements of a certain
depth and less than 8' ceiling height as an exemption to inclusion in the framed area
calculations.
6. Should the area included between the floor and ceiling of an underground structure be
counted as a story? (ZPC)
The current definition of a story in the zoning regulations would include the basement as
a story for compliance with the 2-%z story rule. If certain basements do not count toward
framed area, then should they be counted as a story? Or if we count the basement area as
a story, should it be counted toward the maximum allowable framed area?
7. What types of uses of an underground structure will be allowed? (ZPC or BSC)
Any enclosure located below base flood elevation is limited to parking, access to the
structure, and storage. We could limit a basement to these uses only and not allow any
habitable areas in a basement.
Attachment "B"
List of Concepts and Guidelines
Excavations and Underground Structures
September 22, 2008
At the meeting on July 10, 2008, the Zoning and Planning Commission compiled a list of agreed
upon concepts and guidelines to use in possible regulation development regarding excavations
and underground structures. Two basic concepts that will apply to all of the possible regulations
are:
1. Keep regulations simple and straightforward
2. Look to swimming pool construction rules and flood regulations for guidance
The basic purposes of the regulations seem to be centered on protection of adjoining properties
and safety of the structures and its occupants. The following concepts and the areas of
responsibility between ZPC and the BSC, as well as affected code references are listed below:
Zoning and Planning Commission {ZPC} rZoning Regulationsl
A. Second form of egress (window) to the rear of property only. {ZPC} [Article II
Definitions; Table 7-2 Setbacks; or Table 7-6 Projections]
B. Basement may only be located beneath building footprint. {ZPC} [Table 7-2 or Table 7-
6]
C. Basement may not be located in an easement. {ZPC} [Table 7-2 or Table 7-6]
D. Basement may not be located closer than 5 feet to the side property line. {ZPC} [Table
7-2]
E. Does not count as pervious area (for underground structure located in a front or rear
yard). {ZPC} [Table 7-6]
F. Limit framed area and number of stories (based on increased density and possible
impact on infrastructure). {ZPC} [Article II Definitions of Framed Area]
G. Limit basement area to in proportion to the footprint of the floor above {ZPC} [Article II
Definitions-either definition of basement or half-story]
H. Restrict uses and occupancies (storage, elevators, and non-sleeping and non-habitable
areas only){ZPC} [Article II Definitions]
Building and Standards Commission {BSC} [Chapter 18 Development Regulations and
Appendix C - Technical Codes Schedule]
A. Special engineering and hydrostatic pressure questions {BSC} [Technical Codes and
Drainage Regulations - Chapter 18]
Attachment "B"
B. Drainage provisions must be included {BSC} [Drainage Regulations-Chapter 18]
C. Sill heights for egress from basement areas {BSC} [Technical Codes]
D. Require a wider staircase (for safety/egress) {BSC} [Technical Codes]
E. Sprinkler requirements for the structure {BSC} [Technical Codes - Fire and/or Building
Code]
F. Assume it will flood and protect against consequences {BSC} [Chapter 18 - Flood
Prevention Regulations prohibit basements in Special Flood Hazard Areas (Zone AE,
100 year floodplain)]
G. No sanitary facilities below grade {BSC} [Technical Codes - Building and/or Plumbing
Code; Flood Prevention Regulations]
H. Vertical (inside) access only (no ramps or exits to outside) {BSC} [Flood Prevention
Regulations]
Regulation of
basements and other
"below-grade spaces"
7-09-09 ZPC Position forward to BSC
Issue ZPC Consensus BSC Consensus
Definition of "below Defer to definition of BSC agrees
grade space" basement in the IRC
Size limit No limit Under footprint of house
only
Counts as framed area No Yes, if use and size limit
changes over 200 Sq.
Ft.
Counts as a story No Defer to the IRC
Height limit None None
Plumbing fixtures Allowed per plumbing Depends on if use
(does not apply to code requirements changes
lines)
Use restriction None Storage or mechanical
equipment only if
greater than 200 Sq. Ft.
Number of emergency Defer to the IRC Defer to the IRC
egress paths (EEP's)
EEP directly to Defer to the IRC Defer to the IRC
outdoors
Indoor swimming pool Not in ZPC purview No
in below grade space
Excavation limits No projection or Refer to staff - depth of
(ratio of distance from encroachment into the excavation will be
property line to depth regulated yards equal to the distance
of hole) (setbacks) allowed at from the property line;
any time during 45 degrees depth
construction or at
finished product.
Location in "footprint" No encroachment into Under footprint of house
of principal building any regulated yards only
(below other building (setbacks): 3/7
space) alternated side yard
setback (narrow lots)
will not be allowed with
basement construction.
Synopsis of the Building & Standards Commission Meeting
September 3, 2009
The subjects of the meeting are as follows:
1. Notices. Rules. Etc. Matters relating to notices, introductions, rules, meeting procedures and
identifying parties.
2. Regular members in attendance: Chairman Bryant Slimp, Gerry Spedale, The alternate voting
members were as follows: Frank Griffin, Dave Miller
3. Regular members not in attendance: and Peter Benjamin, Dave Flame, Brian Hoogendam, J.
Denis Powers.
4. Meetine Minutes. Matters relating to discussion and approval of the meeting minutes of August
6, 2009 and August 20, 2009. Both were approved with changes.
5. Docket Number 2009-03 reearding property at 5410 Kirby. West University Place. Texas
77005 (Variance)
No one was in attendance and Mr. Dave McMahan was notified via fax with a
n recem .
Basements and other subterranean structures including ordinance amendments, updates and
related matters. Mr. David Eastwood, PE, Mr. Robert Cunningham, PE and Mr. Lynn Ratcliff, PE
all spoke on the subject of basements.
Do's and Don'ts:
Do's:
• Require them to have a minimum of a 12 inch cast-in-place reinforced concrete
foundation wall.
• Require them to have a standby generator.
• Require them to be provided with a sump pump system.
• Require an exterior drainage system.
• Require water proofing on the exterior of the basement wall.
• Require any shoring to be designed by a registered professional engineer.
• Require a 2:1 ratio of distance to side property line to depth of excavation or install
engineered soldier pilings (not driven but drilled) to protect adjacent property.
Don'ts
• Don't allow foundation walls to be constructed using concrete masonry units (CMU'S)
Consensus of all three engineers was basements can be designed to structurally function however
they don't recommend them being allowed in West University Place.